For both IC-485S / IC-485SI units, set SW1 to DCE or DTE depending on what type of
device the IC-485S / IC-485SI will plug into (if it will plug into a DCE device, configure it
for DTE, and vice versa).
For both IC-485S / IC-485SI units, set SW2 to TxON, RxON.
Point-to-Point 4 Wire Half Duplex
Point-to-Point Half Duplex uses straight through four wire cabling, as shown in the
diagram below.
For both IC-485S / IC-485SI units, set SW1 to DCE or DTE depending on what type of
device the IC-485S / IC-485SI will plug into (if it will plug into a DCE device, configure it
for DTE, and vice versa).
For both IC-485S / IC-485SI units, set SW2 to TxRTS, RxRTS.
2.
Multidrop
A Multidrop configuration is one in which more than two devices are linked for communication using
several IC-485S / IC-485SI units.
One of the devices that one of the IC-485S / IC-485SIs connects to is designated as the Master
device. All the remaining devices that the rest of the IC-485S / IC-485SIs connect to are designated as
Slave devices. There are two configurations: Multidrop Full Duplex, and Multidrop Half Duplex.
Multidrop 4 Wire Full Duplex
Multidrop Full Duplex uses reverse four wire cabling to link all the connected IC-485S /
IC-485SI units:
1.